FA 510/515 - Dew point sensor for refrigeration dryers

Monitoring a compressed air refrigeration dryer is critical to increase energy efficiency, ensure product quality, prevent damage to machinery, identify maintenance needs and achieve cost savings. This contributes to the smooth operation of compressed air systems in various industrial applications.

The sensor technology and evaluation electronics of our sensors have undergone continuous improvements. This implies an increased precision at varying ambient temperatures and a higher signal resolution of the sensor. Like their predecessor models, the new dew point sensors are characterized by long-lasting stable and reliable measurement results. The sensor element is insensitive to condensation and is protected from direct contact with contaminated particles by the stainless-steel sintered cap.

to the request

The product has been added to the request.
to the request

Details

  • Ideal for refrigeration dryer applications with an accuracy of +/- 1°C in the measuring range -20...+50°Ctd.
  • Gas-independent measurement, also suitable for other, non-corrosive gases
  • Compact design, ideal for dryer installations
  • Robust design, protection class IP 66
  • Condensation insensitive sensor element
  • Long-term stability and drift-resistant, thus optimized calibration intervals
  • Fast adaptation time, especially from dry to wet conditions
  • BSP, NPT or UNF thread
  • Analog output 4...20 mA (two- or three-wire) and Modbus RTU (RS 485) interface
  • Measured values available in different units, pressure dew point [°Ctd], temperature [°C], rel. humidity [%rh], abs. humidity [g/m³], degree of humidity [g/kg], humidity fraction V/V [ppmV/V], water vapor partial pressure [hPa], atmospheric dew point [°Ctd.atm].
  • On-site sensor diagnostics with handheld device or CS Service Software

Similar products

FA 500 - Dew point sensor with integrated display and alarm relay

Ideal instrument for dew point measuring for all kinds of dryers.

More

FA 510/515 - Dew point sensor for adsorption dryers

For residual moisture measurement after desiccant dryers/ membrane dryers from -80 to 20°Ctd. New: with Modbus-RTU interface.

More

Dew point measurement DS 52-set for desiccant dryers

with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -80 to 20°Ctd.

More

Dew point measurement DS 52-set for refrigeration dryers

with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -20 to 50°Ctd.

More

Accessories

Standard measuring chamber

for compressed air up to 16 bar

More

Control and calibration set for dew point sensors

is screwed onto the dew point sensor and therefore enables an easy and low-priced possibility for on-site control and calibration down to -20°Ctd.